OL16-32 RCBO
- Model Number:
- Place of Origin: , China
- Minimum Order Quantity: 0 Pieces
- Supply Capacity: 0 Pieces/month
- MemberShip: Free Member
- Inquiry Now
ol16-32 rcbo Description
Product Name: ol16-32 rcbo
Description
Residual current characteristics: AC
Pole No.: 1P+N
Rated current (A): 6, 10, 16, 20, 25, 32
Rated voltage: 230V AC
Summarize
·Elegant appearance; cover and handle in arc shape make comfortable operation.
·Contact position indicating window
·Transparent cover designed to carry label.
·In case of overload to protected circuit, RCBO handle trips and stays at central position, which enables a quick solution to the faulty line. The handle cannot stay in such position when operated manually.
·MCB handle can be locked either at “ON” position or at“OFF” position to prevent unwanted operation of the product.
·Provides protection against earth fault/leakage current, short-circuit and overload
·High short-circuit capacity
·Provides complementary protection against direct contact by human body.
·Effectively protects electric equipment against insulating failure
·Contact position indication
·Provides protection against over-voltage
Order note
Minimum order quantity, time during the order to delivery;
Need to indicate type , specification , rated current , number of poles, quantity of the products while ordering.
Product's advantage
Our products have the guarantee period of 36 calendar months,that is a high quality and reliability;
our products have an excellent ratio between price and quality ,you can possess them by competitive price and high quality;
The fast and flexible production form aim at the customer require;
The deliveries exactly in accordance with customer orders
The fast transportation.
Adopt electromagnetic style release , can play a leak electricity and electric shock protecting role while breaking in zero Line.
Normal operation and mounting requirement
·Circumstance temperature -5°C~ +40°C, average temperature not exceeding 35°C.
·Altitude above sea level less than 2000 m.
·Humidity not exceeding 50% at 40°C and not exceeding 90% at 25°C.
·Installation class II or III.
·Pollution class II.
·Installation method DIN Rail mounting type.
·The external magnetism shall not be more than 5 times of terrestrial one.
·Product shall be installed vertically at the place where there shall be no severe impact and vibration. The product is switched on when the handle is at upper position.
Main technical parameters
Type : electronic type
Residual current characteristics: AC
Pole No.: 1P+N
Tripping curve: B, C
Rated short-circuit capacity: 10000A
Rated current (A): 6, 10, 16, 20, 25, 32
Rated voltage: 230V AC
Rated frequency: 50/60Hz
Rated residual operating current(A): 0.03, 0.1
Tripping duration: instantaneous≤0.1s
Electro-mechanical endurance: 4000 cycles
Connection terminal: pillar terminal with clamp
Connection capacity:
Flexible conductor 10mm2
Rigid conductor 16mm2
Installation:
On symmetrical DIN rail 35mm
Panel mounting
Residual current characteristics: AC
Pole No.: 1P+N
Rated current (A): 6, 10, 16, 20, 25, 32
Rated voltage: 230V AC
Summarize
·Elegant appearance; cover and handle in arc shape make comfortable operation.
·Contact position indicating window
·Transparent cover designed to carry label.
·In case of overload to protected circuit, RCBO handle trips and stays at central position, which enables a quick solution to the faulty line. The handle cannot stay in such position when operated manually.
·MCB handle can be locked either at “ON” position or at“OFF” position to prevent unwanted operation of the product.
·Provides protection against earth fault/leakage current, short-circuit and overload
·High short-circuit capacity
·Provides complementary protection against direct contact by human body.
·Effectively protects electric equipment against insulating failure
·Contact position indication
·Provides protection against over-voltage
Order note
Minimum order quantity, time during the order to delivery;
Need to indicate type , specification , rated current , number of poles, quantity of the products while ordering.
Product's advantage
Our products have the guarantee period of 36 calendar months,that is a high quality and reliability;
our products have an excellent ratio between price and quality ,you can possess them by competitive price and high quality;
The fast and flexible production form aim at the customer require;
The deliveries exactly in accordance with customer orders
The fast transportation.
Adopt electromagnetic style release , can play a leak electricity and electric shock protecting role while breaking in zero Line.
Normal operation and mounting requirement
·Circumstance temperature -5°C~ +40°C, average temperature not exceeding 35°C.
·Altitude above sea level less than 2000 m.
·Humidity not exceeding 50% at 40°C and not exceeding 90% at 25°C.
·Installation class II or III.
·Pollution class II.
·Installation method DIN Rail mounting type.
·The external magnetism shall not be more than 5 times of terrestrial one.
·Product shall be installed vertically at the place where there shall be no severe impact and vibration. The product is switched on when the handle is at upper position.
Main technical parameters
Type : electronic type
Residual current characteristics: AC
Pole No.: 1P+N
Tripping curve: B, C
Rated short-circuit capacity: 10000A
Rated current (A): 6, 10, 16, 20, 25, 32
Rated voltage: 230V AC
Rated frequency: 50/60Hz
Rated residual operating current(A): 0.03, 0.1
Tripping duration: instantaneous≤0.1s
Electro-mechanical endurance: 4000 cycles
Connection terminal: pillar terminal with clamp
Connection capacity:
Flexible conductor 10mm2
Rigid conductor 16mm2
Installation:
On symmetrical DIN rail 35mm
Panel mounting
Product Tags: Circuit Breaker